{"product_id":"glp-gip-tz","title":"GLP\/GIP-TZ","description":"\u003cp\u003eGLP\/GIP-Tz is a lyophilized dual-agonist research ligand for GIP and GLP-1 receptor assays, available in mass formats from 5mg to 120mg. Higher-mass formats support preparation of a single laboratory stock for multiple assays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor laboratory research use only. Not for use in humans or animals.\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp class=\"p1 wp-block-paragraph\"\u003eThis product is the synthetic peptide ligand known as GLP\/GIP-Tz, supplied across a range of mass units (5mg–120mg) to suit different laboratory scales. It is a linear 39- amino acid chain that functions as a Dual-Agonist, targeting two distinct incretin receptor pathways simultaneously. Smaller units suit single-assay or exploratory use, while higher-mass units are engineered for high-throughput laboratories: they allow researchers to create a single concentrated Stock Solution, supporting consistent stock preparation for cell culture assays, without pooling multiple smaller containers\u003cspan class=\"s1\"\u003e. \u003c\/span\u003eResearch Mechanism: In laboratory receptor research, this ligand is utilized to study:\u003c\/p\u003e\n\u003col class=\"wp-block-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynergistic Signaling \u003c\/strong\u003e: How activating the GIP receptor alongside the GLP-1 receptor alters cellular energy homeostasis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLipid Substrate Utilization \u003c\/strong\u003e: Investigating how dual-pathway modulation influences adipocyte (fat cell) metabolism in vitro.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReceptor Kinetics\u003c\/strong\u003e : Measuring binding affinity without the interference of insulinogenic feedback loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynergistic Mechanism of Action \u003c\/strong\u003e: Distinct from mono-target ligands, GLP\/GIP-Tz exhibits simultaneous affinity for both GIP and GLP-1 recognition sites. This dual-receptor occupancy modulates intracellular cAMP flux, facilitating the investigation of synergistic signaling pathways in isolated cell cultures.”\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eChemical Diagram\u003c\/h2\u003e\n\u003ch3 class=\"wp-block-heading\"\u003eChemical Diagram of GLP\/GIP-Tz\u003c\/h3\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" data-attachment-id=\"114510\" data-permalink=\"https:\/\/profoundaminos.com\/?attachment_id=114510\" data-orig-file=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand.webp\" data-orig-size=\"1600,925\" data-comments-opened=\"1\" data-image-title=\"GLP\/GIP-Tz Chemical Structure GIP-GLP-1 Receptor Ligand\" data-image-description=\"\u0026lt;p\u0026gt;High-resolution 2D molecular structure of GLP\/GIP-Tz (CAS 2023788-19-2), illustrating its peptide backbone and lipid modification. Supplied as a lyophilized reagent vial for stock solution preparation in receptor affinity and metabolic research applications.\u0026lt;\/p\u0026gt;\n\u0026lt;p\u0026gt;Select 57 more words to run Humanizer.\u0026lt;\/p\u0026gt;\" data-image-caption=\"\u0026lt;p\u0026gt;Chemical structure of GLP\/GIP-Tz a high-mass lyophilized reagent used as a GIP\/GLP-1 receptor affinity ligand in laboratory research.\u0026lt;\/p\u0026gt;\" data-large-file=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1024x592.webp\" class=\"wp-image-114510\" src=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-300x173.webp\" alt=\"2D chemical structure of GLP\/GIP-Tz 75 lyophilized reagent showing peptide backbone and lipid chain modification\" width=\"408\" height=\"235\" srcset=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-300x173.webp 300w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1024x592.webp 1024w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-768x444.webp 768w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1536x888.webp 1536w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand.webp 1600w\" sizes=\"auto, (max-width: 408px) 100vw, 408px\"\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e2D chemical structure of GLP\/GIP-Tz lyophilized reagent showing peptide backbone and lipid chain modification GLP\/GIP-Tz Lyophilized Reagent Vial for Stock Solution – GIP\/GLP-1 Receptor Affinity Ligand- CAS 2023788-19-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Status\u003c\/strong\u003e : Research Use Only (RUO). Not for use in humans or animals.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eComparative Research Context :\u003c\/h2\u003e\n\u003cp\u003eReceptor Ligand Research Context\u003c\/p\u003e\n\u003cfigure class=\"wp-block-table\"\u003e\n\u003ctable class=\"has-fixed-layout\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eGLP\/GIP-Tz (Dual-A)\u003c\/th\u003e\n\u003cth\u003eGLP-1-Sm (Single-A)\u003c\/th\u003e\n\u003cth\u003eGLP\/GIP\/GLC-Rt (Triple-A)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Receptors\u003c\/td\u003e\n\u003ctd\u003eGIP + GLP-1\u003c\/td\u003e\n\u003ctd\u003eGLP-1 Only\u003c\/td\u003e\n\u003ctd\u003eGIP + GLP-1 + Glucagon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Action\u003c\/td\u003e\n\u003ctd\u003eSynergistic Modulation\u003c\/td\u003e\n\u003ctd\u003eAgonist Signaling\u003c\/td\u003e\n\u003ctd\u003eMulti-Pathway Flux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResearch Focus\u003c\/td\u003e\n\u003ctd\u003eEnergy Homeostasis\u003c\/td\u003e\n\u003ctd\u003eGLP-1R Signaling\u003c\/td\u003e\n\u003ctd\u003eMulti-Receptor Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Type\u003c\/td\u003e\n\u003ctd\u003eDual-Receptor Binding\u003c\/td\u003e\n\u003ctd\u003eSingle-Receptor Binding\u003c\/td\u003e\n\u003ctd\u003eTriple-Receptor Binding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eWHY SOURCE FROM PROFOUND AMINOS\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Format Flexibility, Single-Stock Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eHigher-mass GLP\/GIP-Tz formats (75mg and above) support preparation of a single laboratory stock without pooling multiple smaller containers. Formats from 5mg to 40mg remain available for smaller-scale assays. Stock homogeneity and reproducibility must be assessed under the selected experimental conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Cold-Chain Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePeptide ligands are sensitive to thermal degradation. We use monitored cold-chain handling within the USA, with shipment from a climate-controlled facility to your laboratory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Sequence Integrity Verification\u003c\/strong\u003e\u003cbr\u003eMass spectrometry supports identity characterization of the 39-amino acid peptide. Consult the lot-specific COA for reported analytical results.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eREGULATORY \u0026amp; COMPLIANCE STATEMENT (RUO)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Classification \u0026amp; Usage Disclaimer :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is strictly classified as a Research Use Only (RUO) reagent.\u003c\/p\u003e\n\u003cp\u003eChemical Reference Standard: It is supplied solely for in-vitro testing and laboratory calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Classification:\u003c\/strong\u003e Laboratory Reagent for research assays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLaboratory Handling:\u003c\/strong\u003e Use appropriate PPE, including gloves and eyewear, during solubilization and materials handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Data :\u003c\/strong\u003e Refer to CAS 2023788-19-2 safety sheets before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Use:\u003c\/strong\u003e For laboratory research use only. Not for use in humans or animals.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is this product intended for human use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This is a Chemical Reference Material for laboratory research use only. Not for use in humans or animals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What do the different mass formats (5mg–120mg) mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach number refers to the total mass of lyophilized material in the container. Smaller formats support smaller-scale assays, while higher-mass formats support laboratory stock preparation across multiple experiments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which solvent systems are relevant to the lyophilized material?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSolution or an assay-compatible buffer may be used as laboratory solvent systems. Assess solubility, stability, solvent compatibility, and the concentration required for the selected assay. Consult the SDS and lot-specific documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How should receptor selectivity be assessed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGLP\/GIP-Tz is studied as a GIP and GLP-1 receptor agonist. Assess selectivity using appropriate receptor-binding assays, controls, and off-target panels. Molecular identity alone does not establish an absence of off-target interactions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Why is the powder quantity visually small?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLyophilization removes much of the water and can leave a compact cake. Visual volume can vary and does not provide a reliable measure of mass. Refer to the labeled mass and lot-specific documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ6: Which receptor class is relevant to this ligand?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGIP and GLP-1 receptors are G-protein-coupled receptors. Laboratory assays can examine receptor engagement and downstream signaling. Claims about other receptor families require specific assay evidence.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ7: What information determines the shelf life?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConsult the lot-specific documentation for the storage period and conditions of the lyophilized material. Stability after solubilization depends on the solvent system, concentration, temperature, and handling conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ8: Do you provide a COA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each batch includes a Certificate of Analysis reporting purity and identity characterization by HPLC and mass spectrometry. Consult the lot-specific COA for the reported results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ9: What is the intended research setting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis reagent is supplied for in vitro testing and laboratory research. All handling should follow the SDS and applicable institutional laboratory procedures. Not for use in humans or animals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ10: What are the storage conditions for this research reagent?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStore lyophilized powder at -20°C, desiccated and protected from light. Consult the supplier documentation and institutional laboratory procedures for materials handling requirements.\u003c\/p\u003e\n\u003ch1\u003eGLP\/GIP-Tz (High-Mass) | Dual-Agonist Ligand | CAS 2023788-19-2 | Profound Aminos\u003c\/h1\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eTECHNICAL SPECIFICATIONS\u003c\/h2\u003e\n\u003cul class=\"wp-block-list\"\u003e\n\u003cli\u003eProduct Ref : GLP\/GIP-Tz (Dual-Agonist Research Reagent)\u003c\/li\u003e\n\u003cli\u003eChemical Class : Dual-Agonist Peptide Ligand\u003c\/li\u003e\n\u003cli\u003eCAS Number : 2023788-19-2\u003c\/li\u003e\n\u003cli\u003eMolecular Formula : C₂₂₅H₃₄₈N₄₈O₆₈\u003c\/li\u003e\n\u003cli\u003eMolecular Weight : ~4813.53 g\/mol\u003c\/li\u003e\n\u003cli\u003eSequence Length : 39 Amino Acids\u003c\/li\u003e\n\u003cli\u003eFormat : Lyophilized Filtered Cake\u003c\/li\u003e\n\u003cli\u003eMass Format : Available in 12 mass units, 5mg–120mg (see strength selector)\u003c\/li\u003e\n\u003cli\u003ePurity : ≥99% (RP-HPLC Verified)\u003c\/li\u003e\n\u003cli\u003eSolubility : Soluble in Solution \/ Buffer\u003c\/li\u003e\n\u003cli\u003eStorage : -20°C (Desiccated)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer : \u003c\/strong\u003eFor Research Use Only (RUO). Not for use in humans or animals.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003eThis product is the synthetic peptide ligand known as GLP\/GIP-Tz, supplied across a range of mass units (5mg–120mg) to suit different laboratory scales. It is a linear 39- amino acid chain that functions as a Dual-Agonist, targeting two distinct incretin receptor pathways simultaneously. Smaller units suit single-assay or exploratory use, while higher-mass units are engineered for high-throughput laboratories: they allow researchers to create a single concentrated Stock Solution, supporting consistent stock preparation for cell culture assays, without pooling multiple smaller containers\u003cspan class=\"s1\"\u003e. \u003c\/span\u003eResearch Mechanism: In laboratory receptor research, this ligand is utilized to study:\u003c\/p\u003e\n\u003col class=\"wp-block-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynergistic Signaling \u003c\/strong\u003e: How activating the GIP receptor alongside the GLP-1 receptor alters cellular energy homeostasis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLipid Substrate Utilization \u003c\/strong\u003e: Investigating how dual-pathway modulation influences adipocyte (fat cell) metabolism in vitro.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReceptor Kinetics\u003c\/strong\u003e : Measuring binding affinity without the interference of insulinogenic feedback loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSynergistic Mechanism of Action \u003c\/strong\u003e: Distinct from mono-target ligands, GLP\/GIP-Tz exhibits simultaneous affinity for both GIP and GLP-1 recognition sites. This dual-receptor occupancy modulates intracellular cAMP flux, facilitating the investigation of synergistic signaling pathways in isolated cell cultures.”\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eChemical Diagram\u003c\/h2\u003e\n\u003ch3 class=\"wp-block-heading\"\u003eChemical Diagram of GLP\/GIP-Tz\u003c\/h3\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" decoding=\"async\" data-attachment-id=\"114510\" data-permalink=\"https:\/\/profoundaminos.com\/?attachment_id=114510\" data-orig-file=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand.webp\" data-orig-size=\"1600,925\" data-comments-opened=\"1\" data-image-title=\"GLP\/GIP-Tz Chemical Structure GIP-GLP-1 Receptor Ligand\" data-image-description=\"\u0026lt;p\u0026gt;High-resolution 2D molecular structure of GLP\/GIP-Tz (CAS 2023788-19-2), illustrating its peptide backbone and lipid modification. Supplied as a lyophilized reagent vial for stock solution preparation in receptor affinity and metabolic research applications.\u0026lt;\/p\u0026gt;\n\u0026lt;p\u0026gt;Select 57 more words to run Humanizer.\u0026lt;\/p\u0026gt;\" data-image-caption=\"\u0026lt;p\u0026gt;Chemical structure of GLP\/GIP-Tz a high-mass lyophilized reagent used as a GIP\/GLP-1 receptor affinity ligand in laboratory research.\u0026lt;\/p\u0026gt;\" data-large-file=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1024x592.webp\" class=\"wp-image-114510\" src=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-300x173.webp\" alt=\"2D chemical structure of GLP\/GIP-Tz 75 lyophilized reagent showing peptide backbone and lipid chain modification\" width=\"408\" height=\"235\" srcset=\"https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-300x173.webp 300w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1024x592.webp 1024w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-768x444.webp 768w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand-1536x888.webp 1536w, https:\/\/profoundaminos.com\/wp-content\/uploads\/2024\/09\/Tirz-75-Chemical-Structure-GIP-GLP-1-Receptor-Ligand.webp 1600w\" sizes=\"auto, (max-width: 408px) 100vw, 408px\"\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e2D chemical structure of GLP\/GIP-Tz lyophilized reagent showing peptide backbone and lipid chain modification GLP\/GIP-Tz Lyophilized Reagent Vial for Stock Solution – GIP\/GLP-1 Receptor Affinity Ligand- CAS 2023788-19-2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Status\u003c\/strong\u003e : Research Use Only (RUO). Not for use in humans or animals.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eComparative Research Context :\u003c\/h2\u003e\n\u003cp\u003eReceptor Ligand Research Context\u003c\/p\u003e\n\u003cfigure class=\"wp-block-table\"\u003e\n\u003ctable class=\"has-fixed-layout\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eGLP\/GIP-Tz (Dual-A)\u003c\/th\u003e\n\u003cth\u003eGLP-1-Sm (Single-A)\u003c\/th\u003e\n\u003cth\u003eGLP\/GIP\/GLC-Rt (Triple-A)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Receptors\u003c\/td\u003e\n\u003ctd\u003eGIP + GLP-1\u003c\/td\u003e\n\u003ctd\u003eGLP-1 Only\u003c\/td\u003e\n\u003ctd\u003eGIP + GLP-1 + Glucagon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Action\u003c\/td\u003e\n\u003ctd\u003eSynergistic Modulation\u003c\/td\u003e\n\u003ctd\u003eAgonist Signaling\u003c\/td\u003e\n\u003ctd\u003eMulti-Pathway Flux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResearch Focus\u003c\/td\u003e\n\u003ctd\u003eEnergy Homeostasis\u003c\/td\u003e\n\u003ctd\u003eGLP-1R Signaling\u003c\/td\u003e\n\u003ctd\u003eMulti-Receptor Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssay Type\u003c\/td\u003e\n\u003ctd\u003eDual-Receptor Binding\u003c\/td\u003e\n\u003ctd\u003eSingle-Receptor Binding\u003c\/td\u003e\n\u003ctd\u003eTriple-Receptor Binding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eWHY SOURCE FROM PROFOUND AMINOS\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Format Flexibility, Single-Stock Option\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eHigher-mass GLP\/GIP-Tz formats (75mg and above) support preparation of a single laboratory stock without pooling multiple smaller containers. Formats from 5mg to 40mg remain available for smaller-scale assays. Stock homogeneity and reproducibility must be assessed under the selected experimental conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Cold-Chain Integrity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePeptide ligands are sensitive to thermal degradation. We use monitored cold-chain handling within the USA, with shipment from a climate-controlled facility to your laboratory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Sequence Integrity Verification\u003c\/strong\u003e\u003cbr\u003eMass spectrometry supports identity characterization of the 39-amino acid peptide. Consult the lot-specific COA for reported analytical results.\u003c\/p\u003e\n\u003ch2 class=\"wp-block-heading\"\u003eREGULATORY \u0026amp; COMPLIANCE STATEMENT (RUO)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRegulatory Classification \u0026amp; Usage Disclaimer :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is strictly classified as a Research Use Only (RUO) reagent.\u003c\/p\u003e\n\u003cp\u003eChemical Reference Standard: It is supplied solely for in-vitro testing and laboratory calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Classification:\u003c\/strong\u003e Laboratory Reagent for research assays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLaboratory Handling:\u003c\/strong\u003e Use appropriate PPE, including gloves and eyewear, during solubilization and materials handling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Data :\u003c\/strong\u003e Refer to CAS 2023788-19-2 safety sheets before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Use:\u003c\/strong\u003e For laboratory research use only. Not for use in humans or animals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"BioLink Analytica","offers":[{"title":"10mg","offer_id":46172898820165,"sku":"GLP\/GIP-TZ-10","price":120.0,"currency_code":"USD","in_stock":true},{"title":"20mg","offer_id":46172898852933,"sku":"GLP\/GIP-TZ-20","price":152.0,"currency_code":"USD","in_stock":true},{"title":"30mg","offer_id":46172898885701,"sku":"GLP\/GIP-TZ-30","price":165.0,"currency_code":"USD","in_stock":true},{"title":"50mg","offer_id":46172898918469,"sku":"GLP\/GIP-TZ-50","price":202.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0729\/0060\/8069\/files\/Retatrutide-10_f75343f2-e64a-42a1-9fd2-206ae995a773.jpg?v=1793219008","url":"https:\/\/www.biolinkanalytica.com\/products\/glp-gip-tz","provider":"BioLink Analytica","version":"1.0","type":"link"}